Data corruption due to noisy receive line
Description
In all modes, except synchronous slave mode, the received data may be corrupted if a glitch to zero shorter than the half-bit occurs on the receive line within the second half of the stop bit.
Workaround
- Either use a noiseless receive line, or
- add a filter to remove the glitches if the receive line is noisy.
USART does not generate DMA requests after setting/clearing DMAT bit
Description
If the DMA is used for data transmission (DMAT = 1 in USART_CR3 register), and the software clears DMAT bit and sets it again to prepare the next transmission, then the peripheral does not generate DMA requests anymore. As a result, data are not transmitted.
Workaround
- Avoid clearing DMAT.
- If clearing DMAT is needed after the end of DMA transfers, once DMAT is cleared, disable and reenable the peripheral through UE bit of USART_CR1 register. This workaround is acceptable only if the peripheral is not used in receiver mode.
- DMAT can be cleared if the next transmission is based on polling/interrupt.
Wrong data received in smartcard mode and 0.5 stop bit configuration
Description
The USART receiver reads wrong data in smartcard mode and 0.5 stop bit configuration.
Workaround
Use the 1.5 stop bit configuration.
Received data may be corrupted upon clearing the ABREN bit
Description
The USART receiver may miss data or receive corrupted data when the auto baud rate feature is disabled by software (ABREN bit cleared in the USART_CR2 register) after an auto baud rate detection, while a reception is ongoing.
Workaround
Do not clear the ABREN bit.
Noise error flag set while ONEBIT is set
Description
When the ONEBIT bit is set in the USART_CR3 register (one sample bit method is used), the noise error (NE) flag must remain cleared. Instead, this flag is set upon noise detection on the START bit.
Workaround
Having noise on the START bit is contradictory with the fact that the one sample bit method is used in a noise free environment.
LPUART
LPUART does not generate DMA requests after setting/clearing DMAT bit
Description
If the DMA is used for data transmission (DMAT = 1 in LPUART_CR3 register), and the software clears DMAT bit and sets it again to prepare the next transmission, then the peripheral does not generate DMA requests anymore. As a result, data are not transmitted.
Workaround
- Avoid clearing DMAT.
- If clearing DMAT is needed after the end of DMA transfers, once DMAT is cleared, disable and reenable the peripheral through UE bit of LPUART_CR1 register. This workaround is acceptable only if the peripheral is not used in receiver mode.
- DMAT can be cleared if the next transmission is based on polling/interrupt.
Possible LPUART transmitter issue when using low BRR[15:0] value
Description
The LPUART transmitter bit length sequence is not reset between consecutive bytes, which could result in a jitter that cannot be handled by the receiver device. As a result, depending on the receiver device bit sampling sequence, a desynchronization between the LPUART transmitter and the receiver device may occur resulting in data corruption on the receiver side.
This happens when the ratio between the LPUART kernel clock and the baud rate programmed in the LPUART_BRR register (BRR[15:0]) is not an integer, and is in the three to four range. A typical example is when the 32.768 kHz clock is used as kernel clock and the baud rate is equal to 9600 baud, resulting in a ratio of 3.41.
Workaround
- On the transmitter side, increase the ratio between the LPUART kernel clock and the baud rate. To do so:
- Increase the LPUART kernel clock frequency, or
- Decrease the baud rate.
- On the receiver side, generate the baud rate by using a higher frequency and applying oversampling techniques if supported.
SPI
RDY output failure at high serial clock frequency
Description
- Twice the APB clock frequency, with data sizes from 8 to 15 bits
- Six times the APB clock frequency, with data sizes from 16 to 23 bits
- Fourteen times the APB clock frequency, with data sizes from 24 to 32 bits
Workaround
None.
Truncation of SPI output signals after EOT event
Description
After an EOT event signaling the end of a non-zero transfer size transaction (TSIZE > 0) upon sampling the last data bit, the software may disable the SPI peripheral. As expected, disabling SPI deactivates the SPI outputs (SCK, MOSI and SS when the SPI operates as a master, MISO when as a slave), by making them float or statically output their by-default levels, according to the AFCNTR bit of the SPI_CFG2 register.
With fast software execution (high PCLK frequency) and slow SPI (low SCK frequency), the SPI disable occurring too fast may result in truncating the SPI output signals. For example, the device operating as a master then generates an asymmetric last SCK pulse (with CPHA = 0), which may prevent the correct last data bit reception by the other node involved in the communication.
Workaround
- Add a delay between the EOT event and SPI disable action.
- Decrease the ratio between PCLK and SCK frequencies.
TIFRE flag wrongly set in slave PCM long frame mode if FIXCH = 1
Description
When FIXCH = 1, the flag TIFRE indicates an error when channel length indicated by WS does not last as expected. In slave PCM long frame mode, TIFRE is wrongly set, indicating a frame error even if it did not occur.
This issue occurs when all the following conditions are met:
- I2SMOD[1:0] = 1 (I2S/PCM mode) in the SPI_I2SCFGR register
- I2SCFG[2:0] = 000 or 001 or 100 (slave modes) in the SPI_I2SCFGR register
- I2SSTD[1:0] = 11 (PCM) and PCMSYNC=1 (PCM long) in the SPI_I2SCFGR register
- FIXCH[1:0] = 1 (channel length given by CHLEN) in the SPI_I2SCFGR register
Workaround
None. Ignore the TIFRE flag.
TIFRE flag never set in slave PCM/I2S mode if FIXCH = 0
Description
When FIXCH = 0, the TIFRE flag in the SPI_SR register is set to indicate a frame error if a new frame synchronization is received while the shift-in or shift-out of the previous data is not complete (early frame error). Instead, this flag is not set, and no frame error is detected.
This issue occurs when all the following conditions are met:
- I2SMOD[1:0] = 1 (I2S/PCM mode) in the SPI_I2SCFGR register
- I2SCFG[2:0] = 000 or 001 or 100 (slave modes) in the SPI_I2SCFGR register
- FIXCH[1:0] = 0 (CHLEN different from 16 or 32) in the SPI_I2SCFGR register
Workaround