ES0621 · Errata sheetSTM32H523xx and STM32H533xx device errata
Download .pdfOpen in the full document

SDMMC

Command response and receive data end bits not checked

Description

The command response and receive data end bits are not checked by the SDMMC. A reception with only a wrong end bit value is not detected. This does not cause a communication failure since the received command response or data is correct.

Workaround

None.

ADC

New context conversion initiated without waiting for trigger when writing new context in ADC_JSQR with JQDIS = 0 and JQM = 0

Description

Once an injected conversion sequence is complete, the queue is consumed and the context changes according to the new ADC_JSQR parameters stored in the queue. This new context is applied for the next injected sequence of conversions.

However, the programming of the new context in ADC_JSQR (change of injected trigger selection and/or trigger polarity) may launch the execution of this context without waiting for the trigger if:
  • the queue of context is enabled (JQDIS cleared to 0 in ADC_CFGR), and
  • the queue is never empty (JQM cleared to 0 in ADC_CFGR), and
  • the injected conversion sequence is complete and no conversion from previous context is ongoing

Workaround

Apply one of the following measures:
  • Ignore the first conversion.
  • Use a queue of context with JQM = 1.
  • Use a queue of context with JQM = 0, only change the conversion sequence but never the trigger selection and the polarity.

Two consecutive context conversions fail when writing new context in ADC_JSQR just after previous context completion with JQDIS = 0 and JQM = 0

Description

When an injected conversion sequence is complete and the queue is consumed, writing a new context in ADC_JSQR just after the completion of the previous context and with a length longer that the previous context, may cause both contexts to fail. The two contexts are considered as one single context. As an example, if the first context contains element 1 and the second context elements 2 and 3, the first context is consumed followed by elements 2 and 3 and element 1 is not executed.

This issue may happen if:
  • the queue of context is enabled (JQDIS cleared to 0 in ADC_CFGR), and
  • the queue is never empty (JQM cleared to 0 in ADC_CFGR), and
  • the length of the new context is longer than the previous one

Workaround

If possible, synchronize the writing of the new context with the reception of the new trigger.

Unexpected regular conversion when two consecutive injected conversions are performed in Dual interleaved mode

Description

In Dual ADC mode, an unexpected regular conversion may start at the end of the second injected conversion without a regular trigger being received, if the second injected conversion starts exactly at the same time than the end of the first injected conversion. This issue may happen in the following conditions:
  • two consecutive injected conversions performed in Interleaved simultaneous mode (DUAL[4:0] of ADC_CCR = 0b00011), or
  • two consecutive injected conversions from master or slave ADC performed in Interleaved mode (DUAL[4:0]of ADC_CCR = 0b00111)

Workaround

  • In Interleaved simultaneous injected mode: make sure the time between two injected conversion triggers is longer than the injected conversion time.
  • In Interleaved only mode: perform injected conversions from one single ADC (master or slave), making sure the time between two injected triggers is longer than the injected conversion time.

ADC_AWDy_OUT reset by non-guarded channels

Description

ADC_AWDy_OUT is set when a guarded conversion of a regular or injected channel is outside the programmed thresholds. It is reset after the end of the next guarded conversion that is inside the programmed thresholds.

However, the ADC_AWDy_OUT signal is also reset at the end of conversion of non-guarded channels, both regular and injected.

Workaround

When ADC_AWDy_OUT is enabled, it is recommended to use only the ADC channels that are guarded by a watchdog.

If ADC_AWDy_OUT is used with ADC channels that are not guarded by a watchdog, take only ADC_AWDy_OUT rising edge into account.

Injected data stored in the wrong ADC_JDRx registers

Description

When the AHB clock frequency is higher than the ADC clock frequency after the prescaler is applied (ratio > 10), if a JADSTP command is issued to stop the injected conversion (JADSTP bit set to 1 in ADC_CR register) at the end of an injected conversion, exactly when the data are available, then the injected data are stored in ADC_JDR1 register instead of ADC_JDR2/3/4 registers.

Workaround

Before setting JADSTP bit, check that the JEOS flag is set in ADC_ISR register (end of injected channel sequence).

ADC slave data may be shifted in Dual regular simultaneous mode

Description

In Dual regular simultaneous mode, ADC slave data may be shifted when all the following conditions are met:
  • A read operation is performed by one DMA channel,
  • OVRMOD = 0 in ADC_CFGR register (Overrrun mode enabled).

Workaround

Apply one of the following measures:
  • Set OVRMOD = 1 in ADC_CFGR. This disables ADC_DR register FIFO.
  • Use two DMA channels to read data: one for slave and one for master.

Output mode not usable with both PSSI_RDY and PSSI_DE signals enabled

Description

In output mode, when both the PSSI_RDY and PSSI_DE signals are enabled (DERDYCFG[2:0] bitfield set to 011, 100, or 111), the PSSI_DE signal may fail to indicate data validity.

As a result, output mode cannot be used when both PSSI_RDY and PSSI_DE signals are enabled.

Workaround

None.

Data transfer from TAMP_BKPxR to key registers must be done only in ascending order when KEYSEL[2:0] is set to 010 or 100

Description

The KEYSEL[2:0] bitfield of the SAES_CR register defines the source of the key information to use in the SAES cryptographic core:
  • When KEYSEL[2:0] is set to 010, the boot hardware key (BHK), stored in tamper-resistant secure backup registers, is entirely transferred into the key registers upon a secure application performing a single read of all TAMP_BKPxR registers (x = 0 to 3 for KEYSIZE = 0, x = 0 to 7 for KEYSIZE = 1).
  • When KEYSEL[2:0] is set to 100, the XOR combination of DHUK and BHK is entirely transferred into the key registers upon a secure application performing a single read of all TAMP_BKPxR registers (x = 0 to 3 for KEYSIZE = 0, x = 0 to 7 for KEYSIZE = 1).

Some revisions of the reference manual may wrongly specify that the read operation can be performed either in ascending or descending order, while it must be performed always in ascending order.

This is a documentation issue rather than a product limitation.

Workaround

No application workaround is required, provided that the read operation to the TAMP_BKPxR registers is always done in ascending order.